DAUDIN - logo2302EN
V1.0.0DAUDIN AH500 Series Modbus TCP Connection -

DAUDIN - logo 1 kunye AH500 Series Modbus TCP Connection Operating Manual

ULuhlu loLungiselelo lweModyuli ye-I/O ekude

Icandelo elinguNomb. Inkcazo Inkcazo
GFGW-RMO IN I-Modbus TCP-to-Modbus RTU/ASCII, i-4 Ports Isango
I-GFMS-RMO IS Master Modbus RTU, I Port UMlawuli oPhambili
GFDI-RMO IN Igalelo leDijithali 16 Channel Igalelo ledijithali
GFDO-RMO IN Imveliso yeDigital 16 Channel / 0.5A Iziphumo zoDijithali
GFPS-0202 Amandla 24V / 48W Ukunikezwa Amandla
GFPS-0303 Amandla 5V / 20W Ukunikezwa Amandla
0170-0101 8 pin RJ45 female connector/RS-485 Interface Imodyuli yojongano

1.1 Inkcazo yeMveliso

  1. Isango lisetyenziswa ngaphandle ukudibanisa ne-AH500 yonxibelelwano port (Modbus TCP)
  2. Umlawuli oyintloko ujongene nolawulo kunye nokucwangciswa okuguquguqukayo kwee-parameters ze-I / O njalo njalo.
  3. Imodyuli yamandla kunye nemodyuli yojongano ikumgangatho we-I/Os ekude kwaye abasebenzisi banokukhetha imodeli okanye uphawu abalukhethayo.

Izicwangciso zeParamitha yesango

Eli candelo lichaza indlela yokudibanisa isango kwi-AH500. Ngolwazi oluneenkcukacha malunga DAUDIN - logo 1, nceda ubhekisele kwi DAUDIN - logo 1 -Series Product Manual

2.1 I-i-Designer Program Setup

  1. Qinisekisa ukuba imodyuli inikwe amandla kwaye iqhagamshelwe kwimodyuli yesango usebenzisa intambo ye-EthernetDAUDIN AH500 Series Modbus TCP Connection - cable
  2. Cofa ukuvula isoftwareDAUDIN AH500 Series Modbus TCP Connection - software
  3. Khetha "Uqwalaselo lwemodyuli yeM Series"DAUDIN AH500 Series Modbus TCP Connection - Uqwalaselo
  4. Cofa kwi icon ethi "Setting Module".
    DAUDIN AH500 Series Modbus TCP Connection - icon
  5. Ngenisa "Imodyuli yokuSeta" iphepha le-M-seriesDAUDIN AH500 Series Modbus TCP Connection - series
  6. Khetha uhlobo lwemo esekelwe kwimodyuli eqhagamshelweyo
    DAUDIN AH500 Series Modbus TCP Connection - imodyuli
  7. Cofa ku "Connect"DAUDIN AH500 Series Modbus TCP Connection - imodyuli1
  8. Izicwangciso ze-IP zemodyuli yesangoDAUDIN AH500 Series Modbus TCP Connection - imodyuli3

Phawula: Idilesi ye-IP kufuneka ibe kwi-domain efanayo nesixhobo somlawuli

Ukuseta uQhagamshelwano lwe-AH500

Esi sahluko sichaza indlela yokusebenzisa inkqubo ye-ISPSoft ukudibanisa i-AH500 kunye nesango. Ngolwazi oluneenkcukacha, nceda ubhekisele kwi-ISPSoft User Manual

3.1 AH500 uQhagamshelwano lweHardware

  1. I-Ethernet port iphezulu kwi-AH500 kwaye inokudityaniswa kwisangoDAUDIN AH500 Series Modbus TCP Connection - isango
  2.  Isango lokuqala le-485 port liqhagamshelwe kwimodyuli yojongano 0170-0101 ngaphambi kokuba idityaniswe kwimodyuli yolawulo ngentambo ye-Ethernet.DAUDIN AH500 Series Modbus TCP Connection - gateway1

3.2 AH500 Ukuseta uQhagamshelwano 

  1. Qalisa i-ISPSoft, yenza entsha file kwaye nqakraza kabini "HWCONFIG" kwicandelo lolawulo lweprojekthi ngasekhohlo ukungena kwiphepha loqwalaselo.DAUDIN AH500 Series Modbus TCP Connection - Setup
  2. Cofa ekunene kwi icon yePLC kwaye ukhethe "Isishwankathelo" phantsi "Ubumbeko lweHardware"DAUDIN AH500 Series Modbus TCP Connection - Hardware
  3. okanye lo mboniso, cofa ku- "Ethernet-Useto oluSiseko"
    DAUDIN AH500 Series Modbus TCP Connection - Ethernet
  4. IV. Cofa kwi "Data Exchange" ngakwesobunxele ukutshintshela kwiphepha loTshintsho lweDatha kwaye ukhethe i-COM PORT efunekayo (i-Ethernet kule meko). Qinisekisa ukuba ukhethe , kungenjalo unxibelelwano lwedatha aluyi kuqaliswa. Khetha "Yongeza" okanye ulungise iindawo ezikhoyo ukuseta unxibelelwanoDAUDIN AH500 Series Modbus TCP Connection - amasimi
  5. "Useto loTshintsho lweDatha" umfanekiso kunye neenkcukacha:
    DAUDIN AH500 Series Modbus TCP Connection - amasimi1
    1. Ukusebenzisa olo nxibelelwano, qiniseka ukuba ujonge "Qalisa"
    2. Xa zininzi kakhulu iidilesi zokufunda nokubhala, yandisa “iMinimum Refresh Cycle”.
    3. DAUDIN - logo 1 imodyuli yolawulo inokwamkela ikhowudi yomsebenzi we-0x17 ngelixa unciphisa ixesha lokunxibelelana ngokubhala kunye nokufunda okunye
    4. Idilesi ye-IP kufuneka ibe yidilesi ye-IP yesango ofuna ukulidibanisa
    5. Kuba "Uhlobo lwesiXhobo esikude", khetha "Isixhobo esiStandard Modbus"
    DAUDIN - logo 1  I-GFDI-RM01N yokuqala inedilesi yerejista ku-1000(HEX)
    DAUDIN - logo 1 I-GFDO-RM01N yokuqala inedilesi yokubhalisa ngo-2000(HE
  6. Nje ukuba useto lugqityiwe, cofa ku-"Khuphela" ukuze useto lufakwe kwi-PLCDAUDIN AH500 Series Modbus TCP Connection - amasimi2
  7. Nje ukuba irejista yokugcina idatha imiselwe ngokulandela imiyalelo engentla kwiprogram ye-ISPSoft, ilungele ukusetyenziswa

DAUDIN AH500 Series Modbus TCP Connection - yokugcina

DAUDIN - logo

Amaxwebhu / Izibonelelo

DAUDIN AH500 Series Modbus TCP Connection [pdf] Incwadi yokusebenzisa
AH500 Series Modbus TCP Connection, AH500 Series, Modbus TCP Connection, TCP Connection, Connection

Iimbekiselo

Shiya uluvo

Idilesi yakho ye-imeyile ayizupapashwa. Iindawo ezifunekayo ziphawulwe *