2302EN
V1.0.0
kunye AH500 Series Modbus TCP Connection Operating Manual
ULuhlu loLungiselelo lweModyuli ye-I/O ekude
| Icandelo elinguNomb. | Inkcazo | Inkcazo |
| GFGW-RMO IN | I-Modbus TCP-to-Modbus RTU/ASCII, i-4 Ports | Isango |
| I-GFMS-RMO IS | Master Modbus RTU, I Port | UMlawuli oPhambili |
| GFDI-RMO IN | Igalelo leDijithali 16 Channel | Igalelo ledijithali |
| GFDO-RMO IN | Imveliso yeDigital 16 Channel / 0.5A | Iziphumo zoDijithali |
| GFPS-0202 | Amandla 24V / 48W | Ukunikezwa Amandla |
| GFPS-0303 | Amandla 5V / 20W | Ukunikezwa Amandla |
| 0170-0101 | 8 pin RJ45 female connector/RS-485 Interface | Imodyuli yojongano |
1.1 Inkcazo yeMveliso
- Isango lisetyenziswa ngaphandle ukudibanisa ne-AH500 yonxibelelwano port (Modbus TCP)
- Umlawuli oyintloko ujongene nolawulo kunye nokucwangciswa okuguquguqukayo kwee-parameters ze-I / O njalo njalo.
- Imodyuli yamandla kunye nemodyuli yojongano ikumgangatho we-I/Os ekude kwaye abasebenzisi banokukhetha imodeli okanye uphawu abalukhethayo.
Izicwangciso zeParamitha yesango
Eli candelo lichaza indlela yokudibanisa isango kwi-AH500. Ngolwazi oluneenkcukacha malunga
, nceda ubhekisele kwi
-Series Product Manual
2.1 I-i-Designer Program Setup
- Qinisekisa ukuba imodyuli inikwe amandla kwaye iqhagamshelwe kwimodyuli yesango usebenzisa intambo ye-Ethernet

- Cofa ukuvula isoftware

- Khetha "Uqwalaselo lwemodyuli yeM Series"

- Cofa kwi icon ethi "Setting Module".

- Ngenisa "Imodyuli yokuSeta" iphepha le-M-series

- Khetha uhlobo lwemo esekelwe kwimodyuli eqhagamshelweyo

- Cofa ku "Connect"

- Izicwangciso ze-IP zemodyuli yesango

Phawula: Idilesi ye-IP kufuneka ibe kwi-domain efanayo nesixhobo somlawuli
Ukuseta uQhagamshelwano lwe-AH500
Esi sahluko sichaza indlela yokusebenzisa inkqubo ye-ISPSoft ukudibanisa i-AH500 kunye nesango. Ngolwazi oluneenkcukacha, nceda ubhekisele kwi-ISPSoft User Manual
3.1 AH500 uQhagamshelwano lweHardware
- I-Ethernet port iphezulu kwi-AH500 kwaye inokudityaniswa kwisango

- Isango lokuqala le-485 port liqhagamshelwe kwimodyuli yojongano 0170-0101 ngaphambi kokuba idityaniswe kwimodyuli yolawulo ngentambo ye-Ethernet.

3.2 AH500 Ukuseta uQhagamshelwano
- Qalisa i-ISPSoft, yenza entsha file kwaye nqakraza kabini "HWCONFIG" kwicandelo lolawulo lweprojekthi ngasekhohlo ukungena kwiphepha loqwalaselo.

- Cofa ekunene kwi icon yePLC kwaye ukhethe "Isishwankathelo" phantsi "Ubumbeko lweHardware"

- okanye lo mboniso, cofa ku- "Ethernet-Useto oluSiseko"

- IV. Cofa kwi "Data Exchange" ngakwesobunxele ukutshintshela kwiphepha loTshintsho lweDatha kwaye ukhethe i-COM PORT efunekayo (i-Ethernet kule meko). Qinisekisa ukuba ukhethe , kungenjalo unxibelelwano lwedatha aluyi kuqaliswa. Khetha "Yongeza" okanye ulungise iindawo ezikhoyo ukuseta unxibelelwano

- "Useto loTshintsho lweDatha" umfanekiso kunye neenkcukacha:

1. Ukusebenzisa olo nxibelelwano, qiniseka ukuba ujonge "Qalisa"
2. Xa zininzi kakhulu iidilesi zokufunda nokubhala, yandisa “iMinimum Refresh Cycle”.
3.
imodyuli yolawulo inokwamkela ikhowudi yomsebenzi we-0x17 ngelixa unciphisa ixesha lokunxibelelana ngokubhala kunye nokufunda okunye
4. Idilesi ye-IP kufuneka ibe yidilesi ye-IP yesango ofuna ukulidibanisa
5. Kuba "Uhlobo lwesiXhobo esikude", khetha "Isixhobo esiStandard Modbus"
※
I-GFDI-RM01N yokuqala inedilesi yerejista ku-1000(HEX)
※
I-GFDO-RM01N yokuqala inedilesi yokubhalisa ngo-2000(HE - Nje ukuba useto lugqityiwe, cofa ku-"Khuphela" ukuze useto lufakwe kwi-PLC

- Nje ukuba irejista yokugcina idatha imiselwe ngokulandela imiyalelo engentla kwiprogram ye-ISPSoft, ilungele ukusetyenziswa

![]()