UniTalk UT-001 Wireless Digital Full Duplex Ixesha elililo IiNdlela ezimbini zeVoice Intercom System

UniTalk UT-001 Wireless Digital Full Duplex Ixesha elililo IiNdlela ezimbini zeVoice Intercom System

About UniTalk

We have been committed to wireless technology research, innovation and development of excellent wireless products.
We have a professional technical research and development team, pursuing product characteristics and customer experience, paying attention to every feedback and improving products in time to meet customer needs.

Iintshayelelo zemveliso

The wireless digital full-duplex real-time two-way voice intercom system with offline voice control for home and office use is to serve you perfectly wherever you are. This is an unprecedented indoor wireless intercom system product, it will bid farewell to the traditional use of intercom, perfect auto answer and hands-free function, and easy monitoring of children or the elderly to avoid emergency situations. The wireless intercom system uses the advanced Digital Enhanced Cordless Telecommunications (DECT) and the high-fidelity processing technology, sound quality is clear, avoid interference, and make your communication more stable and confidential.

Offline Voice Command Control– The offline voice command control does not require a connection to a WIFI network and is not limited by the usage environment. The biggest significance of offline voice command control is that it can completely free your hands and make it easy to operate. Suitable for people with limited mobility.

Impendulo ezenzekelayo– Usually, we use the intercom that we need to press the call button on the intercom before making a call. The automatic answering function can answer automatically without pressing the answer button.

Audible and visual prompts– Incoming calls with sound and light prompts are more friendly for people with hearing or visual impairments.

Group call- The Group call function that can support one to many calls at the same time.

Monitor function- Easy monitoring of children or the elderly to avoid emergency situations.

Long Distance Wireless- The wireless communication range between FP (Base) and PP unit can up to 1/4mile (400 Meters) in a clear or unobstructed space. If based on the FP (Base) unit as the center, the distance between PP and PP unit can be extended to 1/2mile (800 Meters).

Kulula ukuyifaka & expandable- This system is plug and play that easy to install and expandable that can be set up within minutes.

Ngaphezuluview

Ngaphezuluview
Ngaphezuluview

Umboniso weLCD

Umboniso weLCD

Indlela yokulinda: LCD backlight is not lit
Imo esebenzayo: LCD displays Ice blue/Green backlight

Phawula: Ice blue backlight for FP (Base) unit Green backlit

Imiyalelo yokusebenza

Vula/Cima

The intercom will power on automatically and the LCD screen will be lighted when the USB 5V is plug in.
Cofa kwaye ubambe i Umqondiso (Hang up) for 3 seconds to turn on/off the intercom.

Set up the intercom

This intercom system is already paired before leaving the factory and users can plug and play it.

Phawula: If the user needs to add a new PP unit that must to be paired and registered on the FP (Base) unit before use.

  • a. How to identify FP (Base) unit and PP units?
    Plug in the USB power and then turn on the intercom, The LCD backlight of the FP(Base) unit will display ice blue and the unit number defaults is 0. The LCD backlight of PP unit will display green and the unit number will be assigned to 1-5.
  • b. Paring method for registration on FP (Base) unit
    Press and hold the VOL+/VOL- button on the FP and PP units respectively for 3 seconds to enter pairing mode, and the icon on LCD will flash. You can hear a successful pairing prompt tone, the system will automatically assign a unit number to the PP unit and the corresponding unit number will be displayed on the LCD.

Please record the unit number of each office / room as following to enable you to rapidly and accurately call others.

Umjelo 0 1 2 3 4 5
Udidi FP (Base Unit) PP PP PP PP PP
Indawo ekuyo isixhobo Egumbini lokuhlala Igumbi lokutyela Igumbi lokulala Ikhitshi igaraji Igumbi lokufunda

Full duplex call mode (one-to-one)

  • a. If there are only 2 units (1 FP+1 PP), pressing the Umqondiso (Call) button can make the call directly.
  • b. If there are multiple devices, you can press the unit number of that you want to call to make a call directly.
  • c. When the called party intercom receives the incoming call signal, it will ring and the unit number of the incoming call will be flashing on the LCD screen. The unit will auto answer if the auto answer function is enabled (Default is enabled) or press the Call button to answer if the auto answer function is disabled.
  • d. If the auto answer function is disabled and you do not answer the call after ringing for 40 seconds, the intercom will exit and return to the standby mode automatically.
  • e. In the calling mode, either party presses the Hung-up button to end the call.

Ukufowuna kweqela

The intercom has a Group call function that can support one to many calls, you just need to press the Umqondiso (Group) button to call all online stations at the same time.

Phawula: The Group call function can only support simultaneous talking between 5 units (1 FP + 4 PP units).

Monitor/VOX (Voice Operated Exchanged) Function

The intercom has a monitor function, which you can use for an elderly care and baby monitor. In order to improve the noise issue during monitoring that you can switch to VOX mode. If the VOX is turned on, as long as the microphone of the intercom detects a speaking sound, it will automatically turn on transmission, achieving “voice controlled” calls.
When the microphone cannot hear sound, the speaker will be muted and will not disturb your rest.

Cofa kuqala i Umqondiso (Monitor) button enter the monitor mode and then press unit number 0-5 to specify the authorized devices allowed to be monitored. The icon of monitor on the LCD will illuminate to indicate this status.

Umzekeloample, the PP unit (1#) is in the baby room and the FP unit (0#) is in the primary bedroom. In order to protect user privacy, if the parents want to monitor the sound of the baby room, they need to press the Monitor button on the PP unit (1#) in the baby room and then select the unit number with 0(FP unit), and then they can monitor the sound of the baby room in the primary bedroom. If you want to switch to VOX mode during monitoring mode, you only need to press and hold the Monitor button on the FP unit for 3 seconds to enter the VOX mode and the VOX icon on the LCD will light up.

Phawula: This monitoring function can work continuously.

Ulawulo lweNqanaba loMqulu

Cofa i IVOLI / VOL- button to adjust the volume level of the ringing tone in standby mode.
Cofa i IVOLI / VOL- button to change the volume level of call in the calling mode.

Qaphela: There are 6 levels of volume control, 1 is the minimum, 6 is the maximum.

Ummiselo wokuphendula ngokuzenzekela

The auto answer function is enabled by default that can completely free your hands to realize full-duplex real-time hands-free call. The recipient does not need to press the Call button to answer the call, the intercom will answer automatically after three rings.

  • a. Press and hold the VOL- button for 3 second to disable the auto answer function that you can head a voice prompt with auto answer turned off.
  • b. Press and hold the VOL- button for 3 second again to enable the auto answer function that you can head a voice prompt with auto answer turned on.

Howling Detect

There will produce a whistling sound when two intercoms are in close proximity during a conversation, so the intercom has a built-in the howling detect function that it will temporarily mute the output of speaker for 5 seconds after detecting howling to avoid the whistling sound, there will display a flashing “H” on the LCD at the same time.
The howling detect function is enabled by default, you can press and hold the VOL+ button for 3 seconds to turn on/off the function and there will be a prompt sound with howling detect turned on/off.

Chimes Selection

Press the Chimes button to change the ringtone between 0-9 that you want to specify your preferred ringtone.

Phawula: This intercom has built-in 10 chimes that you can to choose from.

Mic Mute function

Short press the MUTE button in calling mode to enter MIC mute mode. Press the Mute button again to unmute.

Phawula: An icon with U will be displayed on the LCD and the backlight of LCD will flash when the microphone is muted.

Ambience light setting

Press and hold the Light button to turn on/off the ambience light.

Short press the Light button to change the color of the ambience light from Green → Ice blue → Blue → Purple → Red → Emerald green.

Phawula: In order to save power and extend battery life, the ambient light is turned off by default.

Charging and Low battery prompt (For battery version only)

Isalathisi sentlawulo

During the charging process, the battery symbol Umqondiso is displayed in a cyclic manner.

After being fully charged, the battery symbol Umqondiso stops cycling.

Isalathiso sebhetri esezantsi

Isimboli yebhetri Umqondiso on the LCD flashes and emits a low battery prompt sound.

Please charge in a timely manner, otherwise it will automatically shut down.

Ulawulo lwelizwi ngaphandle kweintanethi

This intercom is equipped with an offline voice recognition chip and you can control this unit with voice commands, which can completely free up your hands and be more friendly to people with limited mobility.

First you need to say the wake-up word with Hi UniTalk to wake up the unit and then say the command word to execute the corresponding function.

Please refer to below voice command for details.

Hayi Amagama omyalelo Uhlobo lomsebenzi Playback Sentence
1 HI-UniTalk Vuka igama Molo, ndingakunceda ngantoni?
2 CALL-UNIT-ONE Ilizwi lomyalelo Calling unit one
3 CALL-UNIT -TWO Ilizwi lomyalelo Calling unit two
4 CALL-UNIT -THREE Ilizwi lomyalelo Calling unit three
5 CALL-UNIT -FOUR Ilizwi lomyalelo Calling unit four
6 CALL-UNIT -FIVE Ilizwi lomyalelo Calling unit five
7 CALL-BASE-UNIT Ilizwi lomyalelo Calling base unit
8 MONITOR-UNIT -ONE Ilizwi lomyalelo Start Monitoring unit one
9 MONITOR-UNIT -TWO Ilizwi lomyalelo Start Monitoring unit two
10 MONITOR-UNIT -THREE Ilizwi lomyalelo Start Monitoring unit three
11 MONITOR-UNIT -FOUR Ilizwi lomyalelo Start Monitoring unit four
12 MONITOR-UNIT -FIVE Ilizwi lomyalelo Start Monitoring unit five
13 MONITOR-BASE-UNIT Ilizwi lomyalelo Start Monitoring base unit
14 GROUP-CALL Ilizwi lomyalelo Start Group call
15 KHANYISA Ilizwi lomyalelo Light turned on
16 KHANYA-CIMA Ilizwi lomyalelo Light turned off
17 UMQULU-PHEZULU Ilizwi lomyalelo Volume turned up
18 UMZULU-PHANTSI Ilizwi lomyalelo IVolumu iye yancitshiswa
19 MAXIMUM-VOLUME Ilizwi lomyalelo Volume at maximum
20 UBUNCINCI-UMQULU Ilizwi lomyalelo Umthamo ubuncinci
21 UMBANE UCIMILE Ilizwi lomyalelo Amandla acimile
22 Welcoming speech Welcome to UniTalk, please say Hi UniTalk to wake me up.
23 Resting language Honey, I’m resting now.

Wireless Transmission Distance Expansion

The wireless communication range between FP and PP unit can up to 1/4mile (400 Meters) in a clear or unobstructed space.
If based on the FP (Base) unit as the center, the distance between PP and PP unit can be extended to 1/2mile (800 Meters).
Wireless Transmission Distance Expansion

Clear pairing records on the FP (Base) unit

Press and hold the VOL+/VOL- on the FP(Base) unit at the same time for 3 seconds and then press the MUTE button continuously 7 times to clear pairing records.

Phawula: If you want to continue using it, you need to refer to the previous Set up the intercom section to re-pair it.

How to installation the intercom

  • a. Place on the desktop
    How to installation the intercom
  • b. Hang on the wall
    How to installation the intercom

Iiparamitha zobuGcisa

Umzekelo No .: UT-001
Ukunikezwa Amandla: DC 5V/1A Input with 6 feet (1.8 meters) USB Type C cable.

Built in Battery (For Battery Version only):

3.7V/2000mAh for FP (Base) Unit
3.7V/1200mAh for PP Unit

Ubomi Bebhetri: Can talk continuously for 14 hours (For Battery Version only)

Umgama woThutho olungenacingo: The distance between FP(Base) and PP unit is ≥1/4 mile(400 Meters) in a clear or unobstructed space.

Phawula: The distance between PP and PP can be extended to 1/2mile (800 Meters) if the FP(Base) unit is placed in the center position.

Ukuphindaphinda komsebenzi:

1921.536MHz-1928.448MHz for US

Ubushushu bomsebenzi:

-4 °F to 140 °F(-20 °C to +60 °C) for working
32°F to 113 °F (0 °C to +45 °C) for battery charging

Ukulungisa ingxaki

The intercom can’t power on

  • a. Check if the USB cable is connected correctly. Or replace another USB cable for testing. It can help us understand whether the problem is on USB cable or the intercom.
  • b. Check if the battery is fully charged. (For Battery Version Only)
  • c. If the problem has not been improved, please contact us to obtain our technical support or replace the faulty unit.

Cannot talk to another intercom

  • a. Please refer to the operating instructions → Set up the intercom to make sure the both intercoms are paired properly.
  • b. Please check the signal strength indicators on the LCDs of both units to confirm if the distance between the two units exceeds the range of use.
  • c. If the problem has not been improved, please contact us to obtain our technical support or replace the faulty unit.

Talk sound is too low

  • a. Make sure the volume level of intercom has been set to the maximum.
  • b. Try to be close to the position of MIC during talk.

There was a howl or static noise during the call

  • a. Maybe the intercoms are too close to each other, please try move away the distance between two intercoms, or move one intercom to another room to eliminate audio self-excitation.
  • b. Some electrical equipment will also interfere with the intercom to cause the static noise. E.g. Microwave Oven, Cell phone or other radio devices, please try to adjust the position to move away from these interference sources.

The system is not getting expected transmission range

  • a. Ensure that all intercoms are installed away from metal obstacles and other electrical equipment interference.
  • b. Please check the signal strength indicators on the LCDs of both intercoms and then try to adjust the placement of the intercom in order to obtain better reception and transmission.
  • c. If the problem has not been improved, please contact us to obtain our technical support or replace the faulty unit.

Ingxelo yeFCC

  1. Esi sixhobo sithobela iCandelo le-15 leMithetho yeFCC. Umsebenzi uxhomekeke kwezi meko zimbini zilandelayo:
    1. Esi sixhobo sisenokungabangeli uphazamiseko oluyingozi.
    2. Esi sixhobo kufuneka samkele naluphi na uphazamiseko olufunyenweyo, kubandakanywa uphazamiseko olunokubangela ukusebenza okungafunekiyo.
  2. Utshintsho okanye uhlengahlengiso olungavunywanga ngokucacileyo liqela elinoxanduva lokuthotyelwa lunokuphelisa igunya lomsebenzisi lokusebenzisa isixhobo.

PHAWULA:

Esi sixhobo sivavanyiwe kwaye safunyanwa ukuba sithobela imida yesixhobo sedijithali soDidi B, ngokungqinelana neCandelo le-15 leMithetho yeFCC.

Le mida yenzelwe ukubonelela ngokhuseleko olufanelekileyo ekuphazamisekeni okuyingozi kwindawo yokuhlala.

Esi sixhobo sivelisa ukusetyenziswa kwaye sinokusasaza amandla amaza erediyo kwaye, ukuba asifakanga kwaye sisetyenziswe ngokuhambelana nemiyalelo, sinokubangela uphazamiseko oluyingozi kunxibelelwano lwerediyo. Nangona kunjalo, akukho siqinisekiso sokuba ukuphazamiseka akuyi kwenzeka kufakelo oluthile. Ukuba esi sixhobo sibangela uphazamiseko oluyingozi kunomathotholo okanye ulwamkelo lukamabonakude, olunokumiselwa ngokucinywa nokulayita isixhobo, umsebenzisi uyakhuthazwa ukuba azame ukulungisa uphazamiseko ngenye okanye ngaphezulu kwezi ndlela zilandelayo:

Jongisa kwakhona okanye uhambise i-eriyali efumanayo.

Yandisa ukwahlukana phakathi kwesixhobo kunye nomamkeli.

Qhagamshela izixhobo kwindawo yokuphuma kwisekethe eyahlukileyo kuleyo apho umamkeli aqhagamshelwe khona.

Dibana nomthengisi okanye igcisa likanomathotholo/kumabonakude ukuze ufumane uncedo.

Ingxelo yoLwazi lwe-SAR

Ifowuni yakho engenazingcingo sisithuthi sikanomathotholo kunye nesamkeli. Iyilwe kwaye yenziwe ukuba ingagqithi kwimida ekhutshwayo yokuvezwa kumandla erediyofrequency (RF) ebekwe yi-Federal Communications Commission kaRhulumente wase-US. Le mida iyinxalenye yezikhokelo ezibanzi kwaye iseka amanqanaba avumelekileyo ombane weRF kuluntu ngokubanzi. Izikhokelo zisekelwe kwimigangatho eyaphuhliswa yimibutho yezenzululwazi ezimeleyo ngokuvavanywa kwamathuba kunye novavanyo olunzulu lwezifundo zenzululwazi.
The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg. * Tests for SAR are conducted with the phone transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value for this model phone when tested for use on the body, as described in this user guide, is 0.216W/Kg (Imilinganiselo enxitywayo yomzimba yohluka kwiimodeli zefowuni, ngokuxhomekeke kwizincedisi ezikhoyo kunye neemfuno zeFCC). Ngelixa kunokubakho umahluko phakathi kwamanqanaba e-SAR eefowuni ezahlukeneyo nakwizikhundla ezahlukeneyo, zonke ziyahlangabezana neemfuneko zikarhulumente zokuvezwa okukhuselekileyo. I-FCC inike uGunyaziso lweZixhobo kule modeli yefowuni kunye nawo onke amanqanaba e-SAR axeliweyo avavanyiweyo njengokuthobela izikhokelo zokuvezwa kweFCC RF. Ulwazi lwe-SAR kule modeli yefowuni luvuliwe file ngeFCC kwaye inokufumaneka phantsi kwecandelo lesiBonelelo seSibonelelo se http://www.fcc.gov/oet/fccid emva kokukhangela

Isazisi seFCC :2BQFX-UT001Additional information on Specific Absorption Rates (SAR) can be found on the Cellular Telecommunications Industry Association (CTIA) web-kwindawo http://www.wow-com.com. * E-United States naseKhanada, umda we-SAR kwiifowuni eziphathwayo ezisetyenziswa luluntu yi-1.6 watts/kg (W/kg) elinganiselwa kwigram enye yethishu. Umgangatho ubandakanya umda omkhulu wokhuseleko ukunika ukhuseleko olongezelelweyo kuluntu kunye nokunika ingxelo ngazo naziphi na iiyantlukwano kwimilinganiselo.

Umsebenzi onxitywe ngumzimba

Esi sixhobo sivavanyelwe imisebenzi eqhelekileyo emzimbeni. Ukuthobela iimfuno zokuvezwa kweRF, umgama wokwahlula ubuncinane oyi-10mm kufuneka ugcinwe phakathi komzimba womsebenzisi kunye nesefowuni, kubandakanywa ne-eriyali. Iikliphu zebhanti zomntu wesithathu, iiholster, kunye nezincedisi ezifanayo ezisetyenziswa sesi sixhobo akufuneki ziqulathe naziphi na izinto zetsimbi. Izincedisi ezigugileyo emzimbeni ezingazifikeleliyo ezi mfuno zisenokungahambelani neemfuno zokuvezwa kweRF kwaye kufuneka ziphetshwe. Sebenzisa kuphela i-eriyali enikiweyo okanye evunyiweyo.

Uxhaso lwabathengi

Thank you for purchasing our product. Please read and keep this manual carefully.
Nceda uzive ukhululekile ukuqhagamshelana nathi ukuba unombuzo.
Uphawu imeyile: unitalkstore@outlook.com

Amaxwebhu / Izibonelelo

UniTalk UT-001 Wireless Digital Full Duplex Ixesha elililo IiNdlela ezimbini zeVoice Intercom System [pdf] Incwadi yokusebenzisa
UT-001F, UT-001P, UT-001 Wireless Digital Full Duplex Real Time Two Way Voice Intercom System, UT-001, Wireless Digital Full Duplex Real Time Two Way Voice Intercom System, Digital Full Duplex Real Time Two Way Voice Intercom System, Full Duplex Real Time Two Way Voice Intercom System, Real Time Two Way Voice Intercom System, Two Way Voice Intercom System, Voice Intercom System, Intercom System, System

Iimbekiselo

Shiya uluvo

Idilesi yakho ye-imeyile ayizupapashwa. Iindawo ezifunekayo ziphawulwe *