BIOSENSORS-LOGO eguqukayo

BIOSENSORS eguquguqukayo AS-2-Rc Ngokupheleleyo iAutomated Laboratory Analysis System

dynamic-BIOSENSORS-AS-2-Rc-Fully-Automated-Laboratory-Analysis-System-PRODUCT

Iinkcukacha

  • Igama lemveliso: heliX + ADAPTER STRAND 2 ngedayi ebomvu Rc
  • Umenziumthombo: Dynamic Biosensors GmbH & Inc.
  • Umzekelo: AS-2-Rc v5.1
  • Ezona mpawu:
    • Amabala ama-2 anee-2 ezahlukeneyo zokulandelelana kweankile kwi-DNA-encoded addressing.
  • Inombolo yoku-oda: AS-2-Rc
  • Ugxininiso: 400 nM
  • Ugcino: Umnqwazi omhlophe, nceda ubone umhla wokuphelelwa kwileyibhile. Gwema imijikelo emininzi yokunyibilikisa ngokuyicaphula i-nanolever.

Imiyalelo yokusetyenziswa kwemveliso

Ukulungiselela | MIX&RUN

  1. Hlanganisa i-Adapter strand 1 - Rc (400 nM) kunye ne-conjugated Ligand strand kunye ne-ligand 1 (500 nM) kwi-1: 1 ratio (v / v).
  2. Hlanganisa i-Adapter strand 2 - Rc (400 nM) kunye ne-conjugated Ligand strand kunye ne-ligand 2 (500 nM) kwi-1: 1 ratio (v / v).
  3. Faka ngokuhlukileyo izisombululo ezibini zesinyathelo 1 kunye ne-2 kwindawo yokushisa kwegumbi kwi-600 rpm imizuzu engama-30 ukuqinisekisa ukuxutywa okupheleleyo.
  4. Hlanganisa izisombululo zenyathelo 1 kunye ne-2 kwi-1: umlinganiselo we-1 (v / v). Isisombululo silungele ukusebenza kwe-biochip.

Ezona mpawu

  • I-Adapter strand 2 yokusebenza kwe-heliX® Adapter Chip Spot 2.
  • Iyahambelana ne-heliX® Adapter Chip.
  • Kubandakanya imicu ye-Adapter ye-50 yokuvuselela.
  • Ilungele uMIX&RUN sample yokulungiselela.
  • I-Adapter strand 2 ithwala idayi ebomvu ye-hydrophobic (Rc) kunye nentlawulo engathathi hlangothi.

heliX® Adapter Chip Overview

Amabala ama-2 anee-2 ezahlukeneyo zokulandelelana kweankile kwi-DNA-encoded addressing.

dynamic-BIOSENSORS-AS-2-Rc-Fully-Automated-Laboratory-Analysis-System-FIG- (1)

Ingcaciso yeMveliso

Umyalelo Inani: AS-2-Rc

Itheyibhile 1. Imixholo kunye noLwazi lokuGcina

dynamic-BIOSENSORS-AS-2-Rc-Fully-Automated-Laboratory-Analysis-System-FIG- (2)

  • Isetyenziselwa uphando kuphela.
  • Le mveliso inobomi obulinganiselweyo beshelufu, nceda ubone umhla wokuphelelwa kwileyibhile.
  • Ukunqanda imijikelo emininzi yokunyibilika komkhenkce nceda uliquot the nanolever

Ukulungiselela | MIX&RUN

Ukuhlanganiswa kwesisombululo kwi-adapter kunye ne-ligand strands:

dynamic-BIOSENSORS-AS-2-Rc-Fully-Automated-Laboratory-Analysis-System-FIG- (3)

  1. Hlanganisa i-Adapter strand 1 - Rc (400 nM) kunye ne-conjugated Ligand strand kunye ne-ligand 1 (500 nM) kwi-1: 1 ratio (v / v).
  2. Hlanganisa i-Adapter strand 2 - Rc (400 nM) kunye ne-conjugated Ligand strand kunye ne-ligand 2 (500 nM) kwi-1: 1 ratio (v / v).
  3. Fukamisa ngokwahlukileyo izisombululo ezibini zenyathelo 1 kunye ne-2 kwi-RT kwi-600 rpm imizuzu engama-30 ukuqinisekisa ukuxutywa okupheleleyo.
  4. Hlanganisa isisombululo sesinyathelo 1 kunye ne-2 kwi-1: umlinganiselo we-1 (v / v). Isisombululo sikulungele ukusetyenziswa kwi-biochip functionalization. Ukuzinza kwesisombululo kuhambelana nokuzinza kwee-molecule ze-ligand.

Itheyibhile 2. Izinto ezongezelelweyo zokusebenza kwendawo 1 kunye nendawo yesalathiso 2.

dynamic-BIOSENSORS-AS-2-Rc-Fully-Automated-Laboratory-Analysis-System-FIG- (4)

Example
Umthamo ofunekayo we-3 yokusebenza: 100 μL kunye noxinzelelo lokugqibela lwe-100 nM.

dynamic-BIOSENSORS-AS-2-Rc-Fully-Automated-Laboratory-Analysis-System-FIG- (5)

Emva kwexesha lokufukamela, xuba ibhodlela yoku-1 kunye ne-2 ukuze ufumane i-100 μL yesisombululo se-DNA esele sikulungele ukusetyenziswa.

Qhagamshelana

Dynamic Biosensors GmbH Perchtinger Str. 8/10 81379 Munich Germany

Dynamic Biosensors, Inc.
300 Trade Centre, Suite 1400 Woburn, MA 01801 USA

Izixhobo kunye neetshiphusi zenziwe ngobunjineli kwaye zenziwe eJamani.

©2024 Dynamic Biosensors GmbH | Dynamic Biosensors, Inc. Onke amalungelo agciniwe.

  1. TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA
  2. Ukuba iprotheni ayizinzile kwi-PE40 (TE40, HE40), nceda ujonge ukuhambelana kwe-buffer kunye neshiti lokuhambelana ne-switchSENSE®.

www.dynamic-biosensors.com

FAQ

Umbuzo: Buthini ubomi beshelufu yemveliso?
A: Imveliso inobomi obunqamlekileyo beshelufu, nceda ubhekisele kumhla wokuphelelwa kwileyibhile.

Umbuzo: Ndifanele ndiyigcine njani imveliso ukugcina uzinzo?
A: Gcina imveliso ngekepusi emhlophe ukuphepha ukuvezwa ekukhanyeni. Gwema imijikelo yokunyibilika komkhenkce ngokucaphula i-nanolever.

Umbuzo: Ndifanele ndilungiselele njani isisombululo se-biochip functionalization?
A: Landela amanyathelo okulungiselela i-MIX&RUN anikezelwe kwincwadi yomsebenzisi ukulungiselela isisombululo se-biochip functionalization.