I-DELL-LOGO

I-DELL EMC OS10 Tshintshela uBumbeko oluSiseko lweSiseko

I-DELL-EMC-OS10-Tshintsho-Esisiseko-Uqwalaselo-Ulungelelwaniso-PRODUCT

Iinkcukacha

  • OS: OS10
  • iQonga lokuQinisekisa: GNS3
  • Ukuhambelana koMxumi: IiWindows
  • Iseva VM File Ubungakanani: GNS3.VM.VMware.ESXI.2.2.31 = 1.4 GB
  • Umxhasi File Ubungakanani: GNS3-2.2.31-all-in-one-regular.exe = 95MB

Imiyalelo yokusetyenziswa kwemveliso

Icandelo I: Sebenzisa i-GNS3 Server VM

  1. Khuphela isoftware ye-GNS3 VM ukusuka apha. Khupha i-zip ekhutshelweyo file.
  2. Ngena kwi-vCenter kwaye ungenise i-GNS3 VM kwindawo yakho ye-ESXi usebenzisa i-OVF Template.
  3. Yongeza ezinye izixhobo kwi-GNS3 Server VM kwitopology enkulu.
  4. Qalisa i-GNS3 Server VM kwaye uqwalasele useto lwenethiwekhi ukuquka nolwabiwo lwedilesi ye-IP.

Icandelo II: GNS3 iFakelo yoMxumi

  1. Khuphela umxhasi we-GNS3 apha.
  2. Faka umxhasi we-GNS3 kwisikhululo solawulo (ilaptop/idesktop).
  3. Qalisa umxhasi we-GNS3 kwaye uqhagamshele kwidilesi ye-IP ye-GNS3 Server VM.

Icandelo III: Sebenzisa izixhobo ze-OS10

  1. Ndwendwela indawo yeNkxaso kaDell kwaye ukhangele kwiNethiwekhi> Iinkqubo eziSebenzayo> iSmartFabric OS10 Software.
  2. Khuphela i-OS10 virtualization files, ukukhetha i-GNS3 bundle yoguqulelo olufunwayo lwe-OS10.
  3. Khupha i-zip ekhutshelweyo file ukwenzela OS10 virtualization.

FAQ

Umbuzo: Ngaba umxhasi we-GNS3 kunye nomncedisi kufuneka babe kuguqulelo olufanayo?

A: Ewe, zombini umxhasi we-GNS3 kunye nomncedisi kufuneka abe noguqulelo olufanayo ngokusebenza okufanelekileyo.

Q: Ngaba i-GNS3 Server VM ingasebenzisa i-DHCP kuqwalaselo lwe-IP?

A: Ewe, kuyenzeka ukuba uqwalasele iseva ye-GNS3 ye-VM ukusebenzisa iinkonzo ze-DHCP ukunika uqwalaselo olufunwayo lwe-IP.

Q: Zeziphi iisetingi zothungelwano ekufuneka ziqwalaselwe uqhagamshelwano phakathi komxumi we-GNS3 kunye nomncedisi?

A: Idilesi ye-IP ye-GNS3 yeseva ye-VM kufuneka ifikeleleke ngedilesi ye-IP yesiKhululo soLawulo se-GNS3, kwaye zombini kufuneka zidityaniswe kuthungelwano lwe-LAN/loLawulo.

OS10 Virtualization Guide

OS10

  • I-Dell EMC Networking OS10 idibanisa eyona Linux ingcono, i-computing evulekileyo, kunye nenethiwekhi ukuqhubela phambili ukusasazwa kwenethiwekhi evulekileyo.
  • Ungalinganisa izixhobo ze-OS10 usebenzisa izixhobo ze-OS10 VM. Izixhobo ze-OS10 VM zisebenzisa isoftwe efanayo ebekwe kwi-OS10-enabled izixhobo zehardware, ngaphandle kwe-hardware abstraction layer.
  • I-OS10 VM i-hardware abstraction layer ilinganisa izixhobo ze-hardware kwindawo ye-VM.

GNS3

  • I-GNS3 yindawo evumela ukulinganisa kwezixhobo zothungelwano kwiimeko eziyinyani. Ingasetyenziselwa ukulinganisa, ukuqwalasela, ukuvavanya, kunye nokujongana nengxaki zothungelwano kwindawo efanisiweyo.
  • I-GNS3 ikuvumela ukuba usebenzise i-topology encinci yenethiwekhi ebandakanya kuphela izixhobo ezimbalwa kweyakho Windows 10 ilaptop, okanye i-topology enkulu yenethiwekhi kwi-VMware ESXi hypervisor okanye iseva yeVMware Workstation.

Iimpawu zokulinganisa ze-OS10

  • Yonke imiyalelo ye-OS10 CLI kunye nojongano oluya kumntla (RESTCONF, SNMP) luyafumaneka kuquka.
  • Ulawulo lwenkqubo (SSH, AAA, DHCP, njalo njalo)
  • Izibuko lolawulo
  • Inqwelomoya yedatha ye-L3 kunye nenqwelomoya yokulawula (usebenzisa ukusebenza kweLinux)

Inxalenye yenkxaso yedatha ye-L2 kunye nenqwelomoya yokulawula (usebenzisa ukusebenza kweLinux):

  • I-LACP
  • VLAN
  • I-LLDP
  • VLT

Unyino lweempawu ze-OS10

  • Akukho nkxaso ye-ACL okanye i-QoS (i-NPU ayifumaneki) — Imiyalelo ye-ACL kunye ne-QoS CLI iyafumaneka (kodwa ayichaphazeli i-traffic)
  • Ukusebenza okulinganiselweyo kwe-L2 (i-NPU ayifumaneki kwi-simulator) - akukho msebenzi wendiza yokulawula umthi

Iimfuno

  • Indawo yokusebenzela okanye ilaptop ene-RAM eyi-16 okanye enkulu ecetyiswayo
  • I-64-bit x86 CPU ene-2 ​​GHz okanye isantya esikhawulezayo esingundoqo (ezimbini-ezingundoqo okanye ezinkulu ziyacetyiswa)
  • I-SSD ene-64 GB indawo ekhoyo
  • Ubume be-Virtualization — ungasebenzisa nokuba yi-Linux okanye i-VMware njenge-host system ye-GNS3 Server VM
  • Umncedisi we VMware ESXi uyacetyiswa ukuba ukulinganisa inethiwekhi enkulu

Ukusasaza i-OS10 kwi-GNS3

Khetha ukhetho lwakho lokuhambisa

  • Ukusasazwa kwendawo
  • GNS3 Server VM Ubeko
  • Esi sikhokelo siya kuchaza amanyathelo afunekayo xa kuthunyelwa i-GNS3 yomncedisi we-VM kumncedisi woMamkeli we-ESXi I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-1

Sebenzisa i-GNS3 Server VM

Kufuneka uqale ufake i-GNS3 Server VM ukuze isebenze njengomncedisi womnatha ofanisiweyo. Umxhasi we-GNS3 ubona uqwalaselo ngelixa iseva ye-GNS3 ilawula kwaye iphumeza ii-OS10 VM.

Khuphela isoftware ye-GNS3 VM

https://www.gns3.com/ https://www.gns3.com/software/download

Ukuba ukhetha ukusebenzisa i-GNS3 Server VM, khetha iQonga lakho lokuSebenza

· Linux KVM

· VMware Player

· I-VMware Workstation

· VMware ESXi (iyacetyiswa)

I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-2
Khupha i-zip ekhutshelweyo file GNS3.VM.VMware.ESXI.2.2.31 = 1.4 GB I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-3
Ngena kwi-vCenter kwaye ungenise i-GNS3 VM kwindawo yakho ye-ESXi - khetha ukusebenzisa i-OVF Template kwaye ukhombise iwizard kwi-GNS3 VM.ova ekhutshelweyo. file I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-4
Ukongeza izixhobo ezingaphezulu kwi-GNS3 Server VM kuya kwenza ukuba kwakhiwe ii-topology ezinkulu I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-5

Qalisa i-GNS3 Server VM kwaye uqwalasele useto lwenethiwekhiI-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-6

Isikhululo soLawulo lwe-GNS3 (umxhasi osebenzisa i-GNS3 GUI) kufuneka abenakho ukufikelela kwi-GNS3 Server VM.

I-GNS3 GUI idinga ukuqhagamshelwa kwi-LAN/Ulawulo womnatha onika uqhagamshelo kwiseva ye-GNS3 vm.

I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-7
  • Qwalasela idilesi ye-IP kwi-eth0 yomncedisi we-GNS3 vm
  • I-GNS3 iseva ye-VM idilesi ye-IP kufuneka ikwazi ukufikelela kwidilesi ye-IP yesiKhululo soLawulo se-GNS3I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-8
  • Kuyenzeka kwakhona ukuqwalasela iGNS3 Umncedisi we VM ukusebenzisa iinkonzo ze DHCP ukunika uqwalaselo olufunwayo lwe IP.
  • Qaphela inkxaso ye-KVM kwi-ESXi kufuneka ibone ngokuzenzekelayo njengeNyanisoI-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-9
Vula uqhagamshelo lwe-console kwi-GNS3 Server vm kwaye uqinisekise idilesi ye-IP esetyenziswa yi-eth0

Le dilesi ye IP izakusetyenziswa kamva xa icebisa umxhasi we GNS3 ukuba ngeyiphi idilesi ye IP amakayisebenzise kumncedisi we GNS3 vm.

I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-10

GNS3 uFakelo loMxumi

Ngoku sele usete i-GNS3 Server VM ukuze isebenze njengomncedisi wakho, ukulungele ukuseta icala lomxhasi wenethiwekhi yakho ukulinganisa izixhobo ze-OS10.I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-11

  • Nje ukuba ufake umxhasi we-GNS3 kwilaptop yakho yeWindows, ungaqhagamshela kwiseva ekude ye-GNS3.
  • Umxhasi we-GNS3 kunye nomncedisi kufuneka abe noguqulelo olufanayo.

Khuphela i-GNS3

Sebenzisa izixhobo ze-OS10

Yiya kwindawo yeNkxaso yeDell, ukhangele zonke iimveliso, phantsi kweziseko zophuhliso, khetha iNethiwekhi, iiNkqubo zokuSebenza, iSmartFabric OS10 Software https://www.dell.com/support/home/en-us/products?app=products.I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-13

  • Khuphela i-OS 10 virtualization files
  • Khetha inqwaba ye-GNS3 yoguqulelo olufunayo lwe-OS10.I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-14
  • Khupha i-zip file okt
  • OS10_Virtualization_10.5.3.2 (malunga nama-807 MB)I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-15
  • Vula umxhasi we-GNS3 kwaye ungenise izixhobo ze-OS10 kuluhlu lwe-GNS3 I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-16
  • Landela iwizadi yesixhobo sokungenisa elizweni I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-17
  • Landela iwizadi yesixhobo sokungenisa elizweni I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-18
  • Phinda amanyathelo okungenisa kwimodeli nganye efunekayo
  • Izixhobo ezithathwe ngaphandle ziya kuvela kwifestile yesandla sasekhohloI-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-19
  • Yenza iprojekthi entsha ye-GNS3 enezitshitshi ze-OS10
  • Tsala isixhobo se-OS10 kwitopology engundoqo view ukongeza iswitshi entsha ye-OS10
  • Iswitshi nganye ye-OS10 isebenzisa i-approx. I-4GB ye-RAMI-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-20
  • Nje ukuba iprojekthi ye-GNS3 iqalisiwe, izixhobo ze-OS10 ziya kuhlala zingagqibekanga kufakelo oluzenzekelayo lwe-OS nge-ONIE.
  • Izixhobo ze-OS10 zinokuthatha ixeshana ukufakela inkqubo yokusebenza ye-OS10 ukuya kulwahlulo olusisiseko kunye nesesibini.I-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-21
  • Vumela imizuzu embalwa ukuba idlule ngaphambi kokuba uzame ukungena nge-admin/adminI-DELL-EMC-OS10-Switch-Basic-Configuration-Virtualization-FIG-22

Amaxwebhu / Izibonelelo

I-DELL EMC OS10 Tshintshela uBumbeko oluSiseko lweSiseko [pdf] Isikhokelo somsebenzisi
OS10 Tshintshela kuqwalaselo oluSiseko, Tshintshela kuqwalaselo oluSiseko, uQeqesho oluSiseko, uBumbeko oluSiseko

Iimbekiselo

Shiya uluvo

Idilesi yakho ye-imeyile ayizupapashwa. Iindawo ezifunekayo ziphawulwe *